Robot calibration

Robot calibration is divided in 4 steps. Each step requires taking a set of measurements. These four steps must be followed in order:

1.Base reference measurements (3 minutes).

2.Tool reference measurements (3 minutes).

3.Calibration measurements (7 minutes, 60 measurements).

4.Validation measurements (7 minutes, 60 measurements).

The following video shows how perform this calibration in 20 minutes: https://youtu.be/Htpx-p7tmYs. The validation measurements (step 4) are not mandatory to calibrate the robot, however they provide an objective point of view of the accuracy results. It is also possible to see the impact of calibrating the robot in one area and validating it in a different area.

Select the button Measure for each of the four sets of measurements. This will open a new window that allows taking new measurements as well as import and export existing measurements in a text file (csv or txt format).

By default, the robot and measurement system are automatically synchronized through the connected robot. If a robot driver is not available, you can still perform robot calibration by generating a robot program which will prompt the user on the teach pendant for manual synchronization.

1.Uncheck Auto synchronize.

2.Click on the Make robot program button.

3.Use the proper post processor to generate the robot program.

Robot Calibration Creaform - Image 26

Measuring the base

These measurements can be performed anywhere in the tool flange if you measure the same target for all the 6 measurements. To start the measurements, select Measure in the Base setup section. The following window will open. Then, select Start Measure and the robot will move sequentially through the scheduled measurements.

Robot Calibration Creaform - Image 27

Close the window when the measurements are completed and the Measurements reference frame will be updated with respect to the robot base frame. If you did not select any reference frame, you can add a reference (select ProgramAdd Reference Frame) and place it under the robot base reference (Drag & Drop in the item tree).

Robot Calibration Creaform - Image 28

The summary will show the position and orientation or the robot reference frame with respect to the calibration reference frame ([x,y,z,w,p,r] format, in mm and radians)

Once this step is completed you can accurately display the workspace of the tracker with respect to the robot in RoboDK in real time.

Measuring the tool

Like the previous section: select Measure in the Tool setup section. The following window will open. Select Start Measure and the robot will move sequentially through the planned measurements. Double click a measurement to continue measuring from that position.

Robot Calibration Creaform - Image 29

The summary will show the calibrated TCP (position and orientation) when the procedure is completed. The definition of the TCP (in the following image “Spindle”) will be updated automatically. If you did not select any TCP, you can add a new one (select “ProgramAdd empty Tool”) and select “Recalculate”.

Robot Calibration Creaform - Image 30

Robot calibration

Select Measure in the Calibration section. The following window will open. Then, select Start Measure and the robot will move sequentially through the planned measurements. Double click a measurement to continue measuring from that position.

Robot Calibration Creaform - Image 31

Close the window when the measurements are completed. The robot will be calibrated automatically and it will display the following message if there are no issues.

Robot Calibration Creaform - Image 32

Finally, the green screen will display some statistics regarding the calibration measurements and how much the accuracy is improved for those measurements.

Robot Calibration Creaform - Image 33

Robot validation

You shouldn’t validate the accuracy of the robot using the same measurements that you used to calibrate the robot, therefore, it is recommended to take additional measurements to validate the accuracy (having a more objective point of view of the accuracy results).

The same calibration procedure must be followed to take the validation measurements. The summary will display the validation statistics. See the following Results Section for more information.